Norsup Heat Pump Type PX Inverter (P20X/32) exploded view & spare parts

This page provides the official exploded-view diagram and full bill of materials (BOM) for the Norsup Heat Pump Type PX Inverter, model P20X/32, carrying Norsup factory reference 7024628. The P20X/32 is a 230 V single-phase full-inverter pool heat pump running on R32 refrigerant, designed for pools of approximately 50–90 m³. Because the PX Inverter platform shares a common chassis architecture across several output ratings, some sub-assemblies — such as the frequency controller plate (pos. 33) — are listed as compatible with the P20X, P26X and P35X series, so it is worth confirming your exact model code before ordering. Use the diagram and the numbered parts list below to identify the component you need and locate its SKU in minutes.

How to use the numbered diagram to find your part

Every call-out number printed on the exploded-view diagram corresponds directly to a numbered row in the parts table — position 7 in the diagram is position 7 in the list, and so on through all 36 positions. The most reliable approach is to locate the area of the unit that contains the suspect part (refrigerant circuit, electrical box, fan assembly, or casing), note the call-out number closest to that component, then find that row in the table to retrieve the SKU. Some positions carry a suffix in parentheses — for example, pos. 3 is labelled “Filter(1)” and pos. 25 “Needle valve(2)” — which indicates that more than one identical item appears in the unit; count the instances on the diagram before ordering so you purchase the correct quantity. Where a SKU is listed in the table, you can add that part directly to your basket; positions shown without a SKU are currently unavailable as individual service parts. Position 36 is a composite row that groups several loose accessories — temperature sensors, rubber feet, union couplers, a display extension cable, winter cover, and drain fittings — each with its own separate part number, so read that row carefully rather than treating it as a single item. Always cross-reference the description in the table against what you see on the unit before placing an order, as a single diagram may cover minor production variants.

Main replaceable assemblies on the Norsup P20X/32

The refrigerant circuit sits at the heart of the machine and includes the rotary compressor (pos. 8), the 4-way reverse valve that switches the unit between heating and cooling modes (pos. 1), the electronic expansion valve that meters refrigerant flow (pos. 2), and the low- and high-pressure switches that protect the circuit — the low-pressure switch rated 0.3 MPa/0.15 MPa (pos. 24, SKU 7011009) and the high-pressure switch rated 3.2 MPa/4.4 MPa (pos. 26, SKU 7011008). The titanium heat exchanger for the P20X/32 (pos. 7, SKU 7024946) is the component through which pool water picks up heat, and titanium construction makes it resistant to chlorinated and salt water. The evaporator (pos. 20) is the large finned coil through which outdoor air passes to give up its energy to the refrigerant. The fan assembly comprises the fan motor ZWS75-A (pos. 17, SKU 7024943), the 500 mm × 145 mm anticlockwise fan blade with a 10 mm centre hole (pos. 16, SKU 7024880), the motor bracket (pos. 19), and the fan protection net (pos. 15). The electrical enclosure houses the main control board 20000-430227 / 302020-00000028 (pos. 29, SKU 7024939), the driver board 2AC32I07WM1 (pos. 32, SKU 7024940), the frequency controller plate for the P20X/26X/35X series (pos. 33, SKU 7025125), and the fan speed control plate specific to the P20X/32 series (pos. 34, SKU 7025128), along with a relay (pos. 31) and reactance (pos. 11). The LED display for the Norsup P-series (pos. 13, SKU 7024942) mounts on the front and is the primary user interface. Water connections are protected by the water flow switch with 32 mm glue adaptor (pos. 27, SKU 7006471), while the pressure meter for R32 gas (0–55 bar, pos. 28, SKU 7026259) allows a technician to read circuit pressure during servicing. The top lid measuring 1115 × 427 mm (pos. 23, SKU 7033050) and the surrounding casing panels — front (pos. 18), back (pos. 21), right (pos. 6), and middle separation panel (pos. 14) — complete the enclosure and protect the internals from the elements.

Choosing between variants and pack sizes

Several electrical connectors appear in the BOM at different positions: the 5-way wire connector (pos. 10, SKU 7011025) and the 2-way wire connector (pos. 30, SKU 7011019) are not interchangeable, so verify the pin count on your loom before ordering. The fan blade at pos. 16 carries a very specific description — 500 mm diameter, 145 mm pitch, 10 mm centre hole, anticlockwise rotation — and fitting a blade with the wrong rotation direction or hole size will prevent it from seating correctly on the motor shaft or producing the required airflow. The frequency controller plate (pos. 33) is listed as compatible with the P20X, P26X, and P35X series, whereas the fan speed control plate (pos. 34) is listed specifically for the P20X/32 series; if you are servicing a P26X or P35X unit, confirm you are on the correct diagram page before ordering pos. 34. For the accessories grouped within pos. 36 — such as the temperature sensor (5K, ref. 7011007), the exhaust temperature sensor (50K, ref. 7024867), the display extension cable and housing for the PX/32 series (ref. 7025131), and the drain hose and hosetail fittings — each item carries its own individual reference number, so treat every accessory as a separate line when building your order.