Hydro Pro Heat Pump Type PX14/32 exploded view & spare parts
Spare parts list
Hydro-Pro - Black Glass Control Display CM404 - 7029494
€194,95
Hydro-Pro - Heat Pump Fan Blade 405mm × 134mm, 3-Blade Anticlockwise - 7024879
€37,45
Hydro-Pro - Heat Pump Fan Motor 40W ZWS40-E51 - 7029495
€225,45
Hydro-Pro - Heat Pump Top Lid 956 × 360 mm (Type P8/32) - 7033047
€97,95
Hydro-Pro - Heat Pump Low Pressure Switch 0.3 MPa / 0.15 MPa - 7011009
€27,95
Hydro-Pro - High Pressure Switch 3.2 MPa / 4.4 MPa (Green) for Type P Heat Pump - 7011008
€27,95
Flotide/MEGA - Heat Pump Water Flow Switch with 32 mm Glue Adapter - 7006471
€51,45
Hydro-Pro - Panel-Mount Refrigerant Pressure Gauge 0–55 bar R32 - 7026259
€44,95
Hydro-Pro - Titanium Heat Exchanger for Type P12/32 Heat Pump - 7024875
€360,95
Hydro-Pro - Heat Pump Control Panel 10m Extension Cable with Housing - 7029497
€150,45
Description
Hydro Pro Heat Pump Type PX14/32 exploded view & spare parts
This page provides the full exploded-view diagram and bill of materials (BOM) for the Bosta Hydro Pro Heat Pump Type PX14/32, listed under factory reference 7028285. The PX14/32 is an inverter-driven, air-to-water pool heat pump that uses R32 refrigerant and a variable-speed compressor to deliver efficient pool heating across a wide operating range. Using the diagram and the numbered parts list below, you should be able to identify the exact component you need within a few minutes, whether you are a pool owner carrying out routine maintenance or a technician completing a service call. All positions shown correspond to genuine Bosta Hydro Pro spare parts as fitted to this model.
How to use the numbered diagram to find your part
Every numbered call-out on the exploded-view diagram corresponds directly to a row in the parts table below it — locate the area of the unit where you see the fault or wear, find the matching position number on the diagram, then read across to the description and SKU in the table. Start by identifying the broad area of the unit (air circuit, refrigerant circuit, water circuit, or electrical enclosure), then narrow down to the sub-assembly, and finally confirm the description matches what you are looking at physically. Pay close attention to position numbers that appear more than once on the diagram — fasteners, brackets, and support plates are sometimes used in several locations on the same unit, so the number you see may point to a shared component. Also note that position 33 in this BOM bundles several accessory items under a single SKU, so read the full description carefully before ordering to confirm the item you need is included. Where a position number has no SKU listed, that part is currently either not available individually or must be sourced as part of a larger assembly — contact us before ordering if you are unsure. Always cross-reference the description column as well as the position number, since diagram reproductions can sometimes vary between print revisions of the same manual.
Main replaceable assemblies on the Hydro Pro Heat Pump Type PX14/32
The air circuit sits at the heart of the unit’s heat-collection function and centres on the fan assembly. Position 4 is the 405 mm × 134 mm anticlockwise fan blade (SKU 7024879), which draws ambient air across the evaporator at position 9; it is driven by the 40 W ZWS40-E51 fan motor at position 6 (SKU 7029495), which is itself mounted on the fan motor bracket at position 10. The plastic fan net (position 3) and fan protection net (position 8) guard these rotating components and are common wear items worth inspecting during any blade or motor replacement. The refrigerant circuit includes the electronic expansion valve (position 20), a 4-way reverse valve (position 23) that enables both heating and cooling modes, a low-pressure switch rated 0.3 MPa/0.15 MPa at position 15 (SKU 7011009), and a high-pressure switch rated 3.2 MPa/4.4 MPa at position 17 (SKU 7011008); a pressure gauge for R32 refrigerant rated 0–55 bar is available at position 25 (SKU 7026259). The water side of the heat exchange process is handled by the titanium heat exchanger PIV 14/32 at position 27 (SKU 7024875), with the water flow switch at position 18 (SKU 7006471) providing the safety interlock that prevents the unit running without adequate water flow. The electrical and control section includes the glass display CM404 at position 2 (SKU 7029494), the centralized controller at position 30 (SKU 7029487), the five-seat connector at position 32 (SKU 7011025), and the switching power supply and extension cable assembly at position 33 (SKU 7029497). The top lid measuring 956 × 360 mm at position 12 (SKU 7033047) and the front frame at position 1 form the outer enclosure, with the chassis at position 28 providing the structural base on which all sub-assemblies are mounted.
Choosing between variants and pack sizes
Position 17 in the BOM covers the high-pressure switch (SKU 7011008) but also references two separate temperature sensor variants in its description: a 5K sensor under SKU 7011007 and a 50K sensor under SKU 7024867. These are distinct components with different resistance characteristics, so confirm which sensor your control board expects before ordering — fitting the wrong resistance value will cause incorrect temperature readings or fault codes. Position 33 similarly groups multiple accessory items — the switching power supply, a 10-metre extension cable, its housing, rubber feet (Φ50 × Φ12 × 30 mm), and a Flotide/MEGA union coupler (50 mm × 1½" PVC-U, 10 bar, glue socket × male thread, part 0100432) — all under SKU 7029497, so check the full item list carefully if you only need one of these accessories. For any position that carries no SKU, please get in touch with us directly, as some components — such as the compressor (position 29), evaporator (position 9), and 4-way reverse valve (position 23) — typically require professional handling and may need to be quoted individually. When ordering structural parts such as the top lid or side plates, verify your unit’s production date if possible, as dimensional specifications can be updated between production runs of the same model range.