Meytec-bufferoplossing – pH 9,18 – fles van 250 ml
Meytec buffer solution – pH 9.18 – bottle 250 ml
The Meytec buffer solution pH 9.18 bottle 250 ml is an alkaline calibration liquid for pH meters and controllers used in swimming pools, spas and other water treatment systems. It provides a stable pH 9.18 reference value so you can calibrate or verify electronic pH probes that need accurate readings in the higher part of the pH scale.
Use of pH 9.18 buffer solution
Electronic pH meters gradually drift as the probe ages and is exposed to chlorinated water, chemicals and changing temperatures. Calibrating with Meytec buffer solution pH 9.18 allows you to correct this drift at the alkaline end of the range, which is useful when the process requires accurate measurements above neutral pH or when you want to confirm that the probe response remains linear.
In many calibration routines, the pH 9.18 buffer is used together with neutral and acidic buffers such as pH 7.00 and pH 4.01. This multi point calibration refines the meter response across the full working range and is recommended for precise pH control in demanding applications.
Fles van 250 ml voor regelmatige kalibratie
The Meytec buffer solution pH 9.18 bottle 250 ml is supplied in a practical screw cap bottle, ideal for users who calibrate or verify their instruments on a regular basis. The 250 ml volume offers a good balance between quantity and shelf life for technicians, service partners and pool operators.
- 250 ml of ready to use alkaline pH 9.18 buffer solution.
- Designfles met stevige dop die herhaaldelijk kan worden geopend en gesloten.
- Geschikt voor tafelmodellen, draagbare testers en vaste pH-regelaars.
Voor het beste resultaat dient bij elke kalibratie slechts een kleine hoeveelheid in een schone recipiënt te worden gegoten, en moet de hoofdfles onmiddellijk na het doseren worden afgesloten om de voorgeschreven pH-waarde te behouden.
Kalibratie met Meytec pH 9,18-buffer
The Meytec buffer solution pH 9.18 bottle 250 ml is compatible with most pH meters that accept external buffer solutions. It is intended for calibration and verification of pH probes used in pools, spas, process tanks and other installations where the pH may rise above neutral or where full range calibration is required.
- Alkalisch referentiepunt voor meerpuntskalibratieroutines.
- Maakt een nauwkeurige afstelling van pH-sensoren bij hogere pH-waarden mogelijk.
- Complements neutral and acidic Meytec buffer solutions for complete calibration.
Calibration procedures should always follow the instrument manufacturer instructions, including the recommended order of buffer values, stabilisation times and temperature compensation.
Voorbeeld van een procedure voor meerpuntskalibratie
A typical multi point calibration using Meytec buffers uses pH 7.00 as the neutral point, pH 4.01 on the acidic side and pH 9.18 on the alkaline side. This combination allows the meter to correct both offset and slope across a wide pH range.
- Spoel de pH-sonde af met schoon water en droog hem voorzichtig af met een zachte doek.
- Kalibreer de meter eerst in een buffer met pH 7,00 en stel de meter zo af dat deze 7,00 aangeeft.
- Spoel de sonde af en kalibreer deze vervolgens in een buffer met pH 4,01 indien het instrument dit vereist.
- Rinse again and pour a small amount of pH 9.18 buffer into a clean container.
- Immerse the probe in the pH 9.18 buffer, wait for a stable value and adjust the reading to 9.18 according to the meter menu.
After calibration the probe can be rinsed and returned to normal measurement with improved accuracy from the acidic region up to the alkaline zone around pH 9.
Aanbevelingen voor opslag en hantering
To keep the Meytec buffer solution pH 9.18 bottle 250 ml within specification, it should be stored in a cool, dry place away from direct sunlight and heat sources. Careful handling helps to avoid contamination and extends the useful life of the buffer solution.
- Sluit de fles altijd direct na gebruik goed af.
- Gebruik voor het werkvolume uitsluitend schone glazen of plastic bakjes.
- Giet gebruikte buffer niet terug in de oorspronkelijke fles.
In combinatie met een juiste opslag van de sondes, reiniging en regelmatige kalibratie met behulp van Meytec-buffers draagt deze oplossing bij aan het behoud van stabiele pH-waarden en ondersteunt het een nauwkeurige doseringsregeling in zwembad- en waterbehandelingssystemen.
In detail
- Alkaline Meytec pH 9.18 reference for extended calibration range
- Praktische fles van 250 ml, geschikt voor regelmatige kalibraties
- Compatibel met de meeste pH-meters, -pennen en -regelaars
- Ideaal als alkalisch meetpunt bij meerpuntskalibraties
- Bij dit flesformaat is een zorgvuldige omgang vereist om besmetting te voorkomen
- Not essential for basic pool checks limited to near neutral pH