Aller au contenu

VGE

VGE UV-C lamps and replacement parts

UV-C is one of the quietest parts of a pool installation: water passes through a stainless steel or plastic housing, is exposed to short-wave ultraviolet light, and leaves with its free-swimming algae and micro-organisms inactivated. Nothing moves, nothing makes a noise, and that is exactly why the lamp inside is so easy to forget. Here you will find VGE UV-C lamps across the T5 and T6 formats, from compact 16W tubes to high-output 325W amalgam lamps, together with housing parts such as the Xclear Jumbo Tech UV-C housing for 40/75W units.

Ce que couvre la gamme

The emphasis is on replacement lamps for UV-C systems that are already installed, which means a wide spread of lengths, wattages and pin configurations rather than a single standard tube. In practice the range includes:

  • T5 low-output lamps such as the 16W 4-pin Base F (F980065 and F980065AM) and the 40W Base F (F980002AM), suited to smaller treatment chambers.
  • T5 amalgam lamps in 40W and 75W with Base M, Base G and other base types, including the 40W Base M (F980172AM) and 75W Base M (F980173AM).
  • VGE Pro T5 amalgam lamps listed by SPT length, for example 40W at 389mm, 75W at 680mm and 75W at 867mm.
  • VGE Pro T6 amalgam lamps for larger flows, from 140W at 867mm through 200W at 1115mm to 325W at 1588mm.
  • Ozone-producing lamps, including a T5 21W 185nm Base H lamp and a T5 75W ozone lamp with Base H.
  • Housings and hardware, such as the Jumbo Tech housing used with 40/75W lamps.

Amalgam, standard and ozone lamps

Standard low-pressure UV-C lamps are the familiar choice for modest pool volumes and shorter chambers. Amalgam lamps use a mercury amalgam rather than liquid mercury, which allows a much higher UV-C output from a tube of similar diameter — the reason a T5 amalgam lamp can be rated at 75W where a conventional tube of the same family is rated far lower. They are the usual fit for larger pools, higher flow rates and units that run long hours.

Ozone lamps are a different proposition again: they also emit at 185nm, which generates ozone in addition to the disinfecting 254nm output. These should only be used in a system that was designed for them, since the housing, downstream materials and any degassing arrangement all have to suit ozone. If the original lamp was not an ozone type, replace like for like.

Identifying the right lamp

Wattage alone is not enough, because the same wattage is produced in several lengths and with several different bases. Work through the following before ordering:

  • Numéro d'article — the code printed on the old lamp or in the manual of the unit is the most reliable reference point. Note that the same lamp can appear with closely related codes.
  • Longueur totale — measure the old tube from end to end, excluding the pins, and compare it with the millimetre figure in the product name, such as 389mm, 680mm, 867mm, 1115mm or 1588mm.
  • Base type — VGE lamps are listed by base letter (F, C, G, H, M, Y and others). The letter describes the pin layout and spacing at the lamp end, and a lamp with the wrong base simply will not seat in the holder.
  • Single-ended or double-ended — check whether the pins are grouped at one end, as on the 4-pin types, or at both ends.
  • Diamètre du tube — T5 and T6 refer to different tube diameters, and the quartz sleeve inside the housing is sized for one of them.

Service, quartz sleeves and lamp life

UV-C output falls gradually long before the lamp stops lighting, so a tube that still glows is not necessarily still disinfecting. Many installations are set up for a lamp change after a season of continuous operation, and the hour counter or service indicator on the control unit is a better guide than appearance.

Isolate the power and relieve pressure before opening a housing. Handle the quartz sleeve carefully, as scale and fingerprints on the glass cut transmission; clean it with a soft cloth and a suitable descaler, and renew the O-rings if they have hardened or flattened. Never look at an operating UV-C lamp outside its housing, and keep the lamp itself free of skin contact so that it is not marked during fitting.

VGE at PoolParthub.com

Here we list VGE UV-C lamps in the T5 and T6 formats, standard and amalgam, with the ozone variants and the Jumbo Tech housing for 40/75W systems, so that an existing installation can be kept running rather than replaced.

The range is organised by wattage, length and base type, with the manufacturer’s article numbers in the product names, which makes it straightforward to match a lamp against the one already in the housing or against the figures in the unit’s documentation.