Hanna Instruments shut-off valve for BL12x / HI5x0 flow cell (BL120-401)

The BL120-401 is a replacement shut-off valve for the flow cell assembly used on Hanna Instruments BL12x series and HI5x0 series pool controllers. It sits in the sample line and lets you stop water flow through the flow cell so probes can be removed, cleaned or calibrated without draining or shutting down the whole circuit. It is supplied as a single valve, not as a complete flow cell.

Do czego pasuje

Designed for the flow cell assemblies fitted to Hanna Instruments BL12x series dosing and control panels and HI5x0 series controllers. It replaces the original inlet or outlet shut-off valve on that flow cell. Check the valve body and thread on your existing part against the replacement before ordering, as older panel revisions may use a different fitting.

Gdzie się znajduje

The valve is mounted in the sample line either upstream of the flow cell (inlet, taken from the pressure side of the circulation pump) or downstream on the return to the pool. Depressurise and isolate the sample line before removing the old valve. Use PTFE tape or a suitable thread sealant on threaded connections and hand-tighten plastic fittings to avoid cracking the body.

Okres eksploatacji

Valve seals and seats wear from constant contact with chlorinated or salt-treated pool water and from repeated opening and closing during probe maintenance. Replace the valve when it drips with the handle closed, when flow cannot be fully stopped, or when the handle becomes stiff or seizes. Inspect it at each probe calibration interval.

Uwagi dotyczące zamawiania

Sold individually as a spare part, not as a kit and not including the flow cell body, probes or fittings. Most flow cell installations use two valves, one on the inlet and one on the outlet, so order the quantity you need. Probes and electrodes for BL12x and HI5x0 controllers are ordered separately.

Informacje dodatkowe

Numer katalogowy: BL120-401
Zgodność: BL12x series and HI5x0 series flow cells
Zastosowanie: Flow cell sample line isolation
Marka: Hanna Instruments
Typ części: Shut-off valve
Dostarczane w postaci: Pojedynczy zawór, część zamienna

Szczegóły

  • Isolates flow cell for probe maintenance
  • Direct replacement for original BL120 valve
  • No need to drain the circuit
  • Low-cost consumable spare part
  • Valve only, flow cell not included
  • Usually two valves needed per flow cell
  • Check fitting size on older panels