Vista esclatada i peces de recanvi de la bomba de calor Hydro-Pro, tipus inversor (tipus Xp10Dcsi+)
Llista de recanvis
Hydro-Pro - Cinturó de calefacció per a evaporador 230V 65W 1900mm - 7020272
56,95 €
Hydro-Pro - Motor de ventilador de bomba de calor ZWB378D02B 120W - 7021812
414,45 €
Hydro-Pro - Pala de ventilador per a bomba de calor inversora 496 mm × 150 mm, orifici de 12 mm, antihorari - 7021815
80,95 €
Flotide/MEGA - Caixa de visualització impermeable per a bomba de calor inversora (tipus Xp05Csie) - 7010543
31,45 €
Hydro-Pro - Controlador amb pantalla LED per a bomba de calor inversora SHHCLEDMM101 - 7020256
226,95 €
Flotide/MEGA - Panell de visualització LED amb Wi-Fi per a bomba de calor inversora (WiFi02iMM011) - 7023600
252,45 €
Flotide/MEGA - Cinturó calefactor de carter de compressor 230V 35W 340mm - 7020267
44,45 €
Manòmetre 0–55 bar R410A - 7010518
47,45 €
Flotide/MEGA - Interruptor de flux d'aigua amb endoll VH-2 (9×7 mm) - 7020257
100,95 €
Flotide/MEGA - Sensor de temperatura de sortida d'aigua TH5 amb endoll (6×4) - 7020262
15,95 €
Hydro-Pro - Titanium Heat Exchanger for Inverter 10 Heat Pump - 7021819
731,95 €
Flotide/MEGA - Sensor de temperatura de l'aigua d'entrada TH6 amb endoll (6×4) - 7020263
15,95 €
Flotide/MEGA - Tap de plàstic per a canonades PP amb rosca exterior ½" 10 bar negre - 0121241
3,45 €
Flotide/MEGA - Sensor de temperatura d'escapament TH3 amb endoll (6×4) - 7020261
15,95 €
Flotide/MEGA - Interruptor d'alta pressió per a bomba de calor 3,6–4,2 MPa - 7024793
21,95 €
Flotide/MEGA - Interruptor de baixa pressió 0,1–0,3 MPa (Bomba de calor A3/32) - 7024791
21,95 €
Flotide/MEGA - Interruptor de baixa pressió 0,2–0,35 MPa (Bomba de calor inversora Xp05Csie) - 7024792
21,95 €
Hydro-Pro - Placa de control principal de la bomba de calor inversora 7 / 10 / 13 kW (53B) - 7020760
559,45 €
Descripció
Vista esclatada i peces de recanvi de la bomba de calor Hydro-Pro, tipus inversor (tipus Xp10Dcsi+)
This page provides the official exploded-view diagram and full bill of materials for the Hydro-Pro Heat Pump, Type Inverter (Type Xp10Dcsi+), referenced by Hydro-Pro factory number 7018546. The XP10DCSI+ is a single-phase inverter pool heat pump in which a variable-speed compressor and fan motor work together to absorb heat from ambient air and transfer it to pool water via a titanium heat exchanger. The diagram covers every serviceable component from the outer casing panels through to the refrigerant circuit and electrical enclosure. Use the numbered call-outs on the diagram alongside the parts list below to identify and order the exact replacement you need — most visitors locate their part within a few minutes.
Com utilitzar el diagrama numerat per trobar la teva peça
Every numbered call-out in the diagram corresponds directly to a row in the parts table: locate the area of the unit where your fault or wear is occurring, note the position number printed on that call-out, then find the matching row in the table to retrieve the SKU. Work methodically from area to number to SKU rather than scanning the whole list at once — it is much faster. Be aware that some position numbers appear more than once in the diagram because the same component is used in multiple locations; position 30 and position 35, for example, are both described as “Wiring cover”, and positions 39 and 46 are both the “Water connection set” (SKU 7014153) used at the inlet and outlet respectively — always verify which instance applies to your repair. Pay close attention to lettered suffixes: positions 23a and 23b are two distinct LED display variants, and positions 65 and 65B are different main board versions — ordering the wrong lettered variant will result in an incompatible part. Where a SKU is listed as null in the table, that component is not currently sold individually through this catalogue; contact our team if you need guidance. If a position number seems ambiguous on a worn or printed diagram, cross-reference the written description in the table to confirm your selection before adding to the basket.
Main replaceable assemblies on the Hydro-Pro Type Inverter (Xp10Dcsi+)
The air-side assembly centres on the fan system: position 17 is the fan motor (ZWB378D02B, 120 W, SKU 7021812) and position 19 is the matched fan blade (496 mm × 150 mm, 12 mm bore, anticlockwise rotation, SKU 7021815); both items must be compatible with one another, so check the rotation direction before ordering. The motor is housed within the motor tube (pos. 18) and supported by the fan motor bracket (pos. 15), with the top frame (pos. 11) and surrounding casing panels — left side (pos. 16), right (pos. 31), front (pos. 20), back (pos. 38), and front grill (pos. 21) — completing the enclosure. The water-side circuit runs through the titanium heat exchanger (pos. 47, SKU 7021819), which is connected to the pool circuit via water connection sets at both ends (pos. 39 and pos. 46, both SKU 7014153), sealed with red and blue rubber rings at positions 40 and 48. Water flow is monitored by the flow switch at position 42 (VH-2 plug, 9 × 7 mm, SKU 7020257), with inlet and outlet temperature sensors at positions 49 and 44 respectively. The refrigerant circuit comprises the compressor (pos. 27) mounted on damping feet (pos. 28), the 4-way valve (pos. 54) with its associated pipework (pos. 53, 55), the electronic expansion valve (pos. 63), and high- and low-pressure switches (pos. 57, 60, and 61). Frost protection is provided by two heating belts: the evaporator heating belt (pos. 14, 230 V / 65 W / 1,900 mm, SKU 7020272) and the compressor heating belt (pos. 29, 230 V / 35 W / 340 mm, SKU 7020267). The electrical enclosure (pos. 66) houses the main inverter board (pos. 65, SKU 7020760) and is fronted by the waterproof display box (pos. 22, SKU 7010543) carrying the LED display. Refrigerant-circuit pressures are read via the pressure gauge at position 32 (SKU 7010518), and system integrity is protected by the high-pressure switch at position 57 (3.6–4.2 MPa, SKU 7024793) alongside two low-pressure switch variants at positions 60 and 61.
Tria entre variants i mides de paquet
The most critical variant choice on this unit is the LED display at position 23: the 23a version (SHHCLEDMM101, SKU 7020256) is the standard inverter display, while 23b (WiFi02iMM011, SKU 7023600) includes integrated Wi-Fi for smartphone control — the two are not interchangeable, so confirm which display your unit was originally fitted with before ordering. A similarly important decision applies to the main board at position 65: SKU 7020760 suits the standard Inverter 7/10 models, whereas the 65B variant (SKU 7020770) is intended for the Inverter 10(B) build and must be paired with the correspondingly suffixed sensor set (the “xxB” variants at positions 44B, 49B, and 56B) — mixing board generations with mismatched sensors will cause incorrect temperature readings. For the temperature sensors at positions 44, 49, and 56, note that each position also carries a “B” variant with a different plug configuration (16 × 4 rather than 6 × 4 for position 56B); always match the plug dimensions to your existing wiring loom. The PP plug at position 50 (½” male thread, 10 bar, SKU 0121241) is a straightforward single-size item, but confirm thread pitch and pressure rating are suitable for your installation before fitting.