Hanna Instruments DO Electrode for HI98194 / HI98195 / HI98196 (HI7698194-2)
Hanna Instruments do electrode for HI98194 / HI98195 / HI98196 (HI7698194-2)
This is the replacement dissolved oxygen (DO) electrode for the Hanna Instruments HI98194, HI98195 and HI98196 portable multiparameter meters. It measures dissolved oxygen in the sample and feeds the reading back to the meter through a dedicated probe connector. It is the standard service part when the original DO sensor no longer holds calibration or has reached the end of its working life.
What it fits
The electrode is designed for the Hanna Instruments HI98194, HI98195 and HI98196 multiparameter portable meters. It plugs into the dedicated dissolved oxygen input of those instruments and is recognised automatically by the meter. It is not interchangeable with pH, ORP or EC electrodes from the same series.
Installation position
Connect the electrode to the DO port on the meter or the multi-sensor probe body, then immerse the sensor tip in the sample or flow chamber. Keep the sensing membrane fully submerged and free of air bubbles during measurement. After connection, allow the sensor to polarise and then run a calibration before taking readings.
Service life
Dissolved oxygen sensors are consumable items and drift as the membrane and internal electrolyte age. Replace the electrode when calibration fails, response becomes slow, or readings remain unstable after membrane and electrolyte service. In continuous commercial pool and process monitoring, service intervals are shorter than in occasional spot-check use.
Ordering notes
Supplied as a single electrode, not as a full meter kit or a calibration solution set. Membranes, electrolyte and calibration solutions are ordered separately. Confirm your meter model number before ordering, as other Hanna probes with similar part codes are not compatible.
Additional information
| Brand: | Hanna Instruments |
|---|---|
| SKU reference: | HI7698194-2 |
| Part type: | Dissolved oxygen (DO) electrode |
| Compatible meters: | HI98194, HI98195, HI98196 |
| Connection: | Dedicated DO probe connector |
| Cable length: | 2 m |
| Sold as: | Single electrode |
In details
- Direct factory replacement for HI98194/98195/98196
- Plug-in connection, no meter modification needed
- Restores accurate dissolved oxygen readings
- Recognised automatically by the host meter
- Consumable sensor, requires periodic replacement
- Calibration needed after every electrode change
- Not compatible with other Hanna meter series