Przejdź do treści

Elektroda pH/ORP firmy Hanna Instruments do mierników HI98194, HI98195 i HI98196 (HI7698194-1)

Hanna Instruments HI7698194-1
1–2 tygodnie
316,95 € Tax Inc.
Wysyłka Wysyłka 1–2 tygodnie
Certyfikowany Certyfikowany sklep internetowy
Łatwe zwroty Łatwe zwroty w ciągu 14 dni
Pytanie Szukasz porady?
Zadaj pytanie

Hanna Instruments pH/ORP electrode for HI98194, HI98195 and HI98196 meters (HI7698194-1)

The HI7698194-1 is a combined pH/ORP electrode designed for Hanna Instruments portable multiparameter meters in the HI98194, HI98195 and HI98196 series. It replaces the pH/ORP sensing element of the multi-sensor probe used for spot-checking pool and process water. As a wear part, it is supplied as a single electrode rather than a complete probe assembly.

Meter compatibility

This electrode is intended for the Hanna Instruments HI98194, HI98195 and HI98196 portable multiparameter meters. It fits the corresponding multi-sensor probe body used with those instruments. It is not interchangeable with benchtop or panel-mounted Hanna controllers that use standard BNC electrodes.

Montaż elektrody

The electrode screws into the dedicated pH/ORP port of the multi-sensor probe after the old unit has been unscrewed and the port cleaned and dried. Check that the O-ring seal is intact and correctly seated before tightening, as water ingress will damage the probe connector. Recalibrate the meter with fresh pH buffers and an ORP standard once the new electrode is installed.

Okres eksploatacji

pH/ORP electrodes are consumables and gradually lose response speed and slope through normal use. Typical working life in commercial pool water is around one to two years, depending on exposure to chlorine, temperature swings and storage conditions. Replace the electrode when calibration fails, readings drift or response becomes noticeably sluggish. Always store the sensing tip wet in storage solution, never dry.

Uwagi dotyczące zamawiania

Sold individually as a replacement electrode, not as a complete probe or kit. Calibration buffers, storage solution and probe cable are ordered separately. Confirm your meter model number before ordering, as other Hanna portable series use different electrode references.

Informacje dodatkowe

Marka: Hanna Instruments
Numer katalogowy: HI7698194-1
Rodzaj produktu: Kombinowana elektroda pH/ORP
Obsługiwane liczniki: HI98194, HI98195, HI98196
Połączenie: Screw-in multi-sensor probe port
Mierzone parametry: pH and ORP
Dostarczane w postaci: Single electrode, not a kit

Szczegóły

  • Genuine Hanna Instruments replacement electrode
  • Measures both pH and ORP in one sensor
  • Direct screw-in fit, no tools required
  • Restores full accuracy of existing meter
  • Consumable part requiring periodic replacement
  • Must be stored wet, never allowed to dry out
  • Only fits HI98194, HI98195 and HI98196 meters