Aller au contenu

Solution tampon Meytec - pH 9.00 - flacon 250 ml

Meytec PHB-900-250D
1 à 3 semaines
14,95  impôts inc.
Expédition Expédition 1 à 3 semaines
Certifié Certifié boutique en ligne
Retours faciles Retours faciles dans les 14 jours
Question Cherchez-vous des conseils ?
Posez votre question

Meytec buffer solution – pH 9.00 – bottle 250 ml

The Meytec buffer solution pH 9.00 bottle 250 ml is an alkaline calibration liquid for pH meters and controllers used in swimming pools, spas and other water treatment systems. It provides a stable pH 9.00 reference value so you can calibrate or verify electronic pH probes operating in the higher part of the pH scale.

Use of pH 9.00 buffer solution

Electronic pH meters gradually drift as the probe ages and is exposed to chemicals, chlorinated water and temperature variations. Calibrating with Meytec buffer solution pH 9.00 allows you to correct this drift on the alkaline side of the range, which is useful when measurements are made above neutral pH or when checking that the probe response remains linear.

In many calibration routines, the pH 9.00 buffer is used together with neutral and acidic buffers such as pH 7.00 and pH 4.01. This multi point calibration refines the meter response across the full working range and is recommended for precise pH control applications.

Bouteille de 250 ml pour étalonnage régulier

The Meytec buffer solution pH 9.00 bottle 250 ml is supplied in a practical screw cap bottle suitable for users who calibrate or verify their instruments frequently. The 250 ml volume offers a good balance between available quantity and shelf life for technicians and pool operators.

  • 250 ml of ready to use alkaline pH 9.00 buffer solution.
  • Design bottle with secure cap for repeated opening and closing.
  • Convient aux pH-mètres de paillasse, aux testeurs portables et aux régulateurs de pH fixes.

For best results, only a small working volume should be poured into a clean container for each calibration, and the main bottle should be closed immediately after dispensing to help maintain the specified pH value.

Calibration with Meytec pH 9.00 buffer

The Meytec buffer solution pH 9.00 bottle 250 ml is compatible with most pH meters that accept external buffer solutions. It is intended for calibration and verification of pH probes used in pools, spas, process tanks and other installations where the pH may rise above neutral or where full range calibration is required.

  • Alkaline reference point for multi point calibration routines.
  • Supports precise adjustment of pH probes at higher pH values.
  • Complements neutral and acidic Meytec buffer solutions.

Calibration procedures should always follow the instrument manufacturer’s instructions, including the recommended order of buffer values, stabilisation times and temperature compensation.

Procédure de calibration multipoints exemple

A typical multi point calibration using Meytec buffers uses pH 7.00 as the neutral point, pH 4.01 on the acidic side and pH 9.00 on the alkaline side. This combination allows the meter to correct both offset and slope across a wide pH range.

  • Rincez la sonde de pH à l'eau claire et séchez-la doucement avec un chiffon doux.
  • Calibrez d'abord dans un tampon pH 7,00 et réglez le pH-mètre sur 7,00.
  • Rincer la sonde, puis calibrer dans un tampon pH 4,01 si requis par l'instrument.
  • Rinse again and pour a small amount of pH 9.00 buffer into a clean container.
  • Immerse the probe in the pH 9.00 buffer, wait for a stable value and adjust the reading to 9.00 according to the meter menu.

After calibration, the probe can be rinsed and returned to normal measurement with improved accuracy from the acidic region up to the alkaline zone around pH 9.

Recommandations de stockage et de manipulation

To keep the Meytec buffer solution pH 9.00 bottle 250 ml within specification, it should be stored in a cool, dry place away from direct sunlight and heat sources. Careful handling helps to avoid contamination and extends the useful life of the buffer.

  • Always close the bottle tightly immediately after use.
  • Utilisez uniquement des récipients en verre ou en plastique propres pour le volume de travail.
  • Do not pour used buffer back into the original bottle.

When combined with proper probe storage, cleaning and regular calibration using Meytec buffers, this solution helps maintain stable pH readings and supports accurate dosing control in pool and water treatment systems.

En détail

Meytec buffer solution – pH 9.00 – bottle 250 ml
14,95 
Buffer solution pH 9.00 for calibration testing.
  • Alkaline Meytec pH 9.00 reference for extended calibration range
  • Practical 250 ml bottle suitable for frequent calibrations
  • Compatible with most pH meters, pens and controllers
  • Ideal as the alkaline point in multi point calibration routines
  • Bottle format requires careful handling to avoid contamination
  • Pas strictement nécessaire pour les vérifications de base de la piscine limitées à un pH proche de la neutralité