Soluzione tampone Meytec - pH 9,00 - flacone da 250 ml
Meytec buffer solution – pH 9.00 – bottle 250 ml
The Meytec buffer solution pH 9.00 bottle 250 ml is an alkaline calibration liquid for pH meters and controllers used in swimming pools, spas and other water treatment systems. It provides a stable pH 9.00 reference value so you can calibrate or verify electronic pH probes operating in the higher part of the pH scale.
Use of pH 9.00 buffer solution
Electronic pH meters gradually drift as the probe ages and is exposed to chemicals, chlorinated water and temperature variations. Calibrating with Meytec buffer solution pH 9.00 allows you to correct this drift on the alkaline side of the range, which is useful when measurements are made above neutral pH or when checking that the probe response remains linear.
In many calibration routines, the pH 9.00 buffer is used together with neutral and acidic buffers such as pH 7.00 and pH 4.01. This multi point calibration refines the meter response across the full working range and is recommended for precise pH control applications.
Flacone da 250 ml per la taratura periodica
The Meytec buffer solution pH 9.00 bottle 250 ml is supplied in a practical screw cap bottle suitable for users who calibrate or verify their instruments frequently. The 250 ml volume offers a good balance between available quantity and shelf life for technicians and pool operators.
- 250 ml of ready to use alkaline pH 9.00 buffer solution.
- Flacone dal design accattivante con tappo di sicurezza che consente di aprirlo e chiuderlo più volte.
- Adatto per misuratori da banco, tester portatili e regolatori di pH fissi.
Per ottenere risultati ottimali, per ogni calibrazione è necessario versare solo un piccolo volume di lavoro in un recipiente pulito e richiudere immediatamente il flacone principale dopo il prelievo, in modo da contribuire a mantenere il valore di pH specificato.
Taratura con tampone Meytec a pH 9,00
The Meytec buffer solution pH 9.00 bottle 250 ml is compatible with most pH meters that accept external buffer solutions. It is intended for calibration and verification of pH probes used in pools, spas, process tanks and other installations where the pH may rise above neutral or where full range calibration is required.
- Punto di riferimento alcalino per le procedure di taratura multipunto.
- Consente una regolazione precisa delle sonde di pH a valori di pH più elevati.
- Complements neutral and acidic Meytec buffer solutions.
Calibration procedures should always follow the instrument manufacturer’s instructions, including the recommended order of buffer values, stabilisation times and temperature compensation.
Esempio di procedura di calibrazione multipunto
A typical multi point calibration using Meytec buffers uses pH 7.00 as the neutral point, pH 4.01 on the acidic side and pH 9.00 on the alkaline side. This combination allows the meter to correct both offset and slope across a wide pH range.
- Sciacquare la sonda pH con acqua pulita e asciugarla delicatamente con un panno morbido.
- Effettuare innanzitutto la calibrazione in un tampone a pH 7,00 e regolare il misuratore in modo che indichi 7,00.
- Sciacquare la sonda, quindi calibrarla in tampone a pH 4,01 se richiesto dallo strumento.
- Rinse again and pour a small amount of pH 9.00 buffer into a clean container.
- Immerse the probe in the pH 9.00 buffer, wait for a stable value and adjust the reading to 9.00 according to the meter menu.
After calibration, the probe can be rinsed and returned to normal measurement with improved accuracy from the acidic region up to the alkaline zone around pH 9.
Consigli per la conservazione e la manipolazione
To keep the Meytec buffer solution pH 9.00 bottle 250 ml within specification, it should be stored in a cool, dry place away from direct sunlight and heat sources. Careful handling helps to avoid contamination and extends the useful life of the buffer.
- Chiudere sempre bene il flacone subito dopo l'uso.
- Utilizzare esclusivamente contenitori puliti in vetro o plastica per il volume di lavoro.
- Non versare il tampone usato nuovamente nel flacone originale.
Se abbinata a una corretta conservazione delle sonde, alla loro pulizia e a una calibrazione regolare con i tamponi Meytec, questa soluzione contribuisce a mantenere valori di pH stabili e garantisce un controllo accurato del dosaggio nelle piscine e negli impianti di trattamento delle acque.
In dettaglio
- Alkaline Meytec pH 9.00 reference for extended calibration range
- Pratico flacone da 250 ml, ideale per calibrazioni frequenti
- Compatibile con la maggior parte dei misuratori di pH, delle penne e dei regolatori
- Ideale come punto alcalino nelle procedure di calibrazione multipunto
- Il formato della bottiglia richiede una manipolazione accurata per evitare la contaminazione
- Non strettamente necessario per i controlli di base della piscina, limitati a un pH quasi neutro