Meytec buffer solution - pH 10.01 - bottle 250 ml
Meytec buffer solution – pH 10.01 – bottle 250 ml 14,95  inc. btw

Description

Meytec buffer solution – pH 10.01 – bottle 250 ml

The Meytec buffer solution pH 10.01 bottle 250 ml is a strongly alkaline calibration liquid for pH meters and controllers used in pools, spas and water treatment systems. It provides a stable pH 10.01 reference value so you can calibrate or verify electronic pH probes that need accurate readings in the higher part of the pH scale.

Use of pH 10.01 buffer solution

Electronic pH meters gradually drift as the probe ages and is exposed to chemicals, chlorinated water and temperature variations. Calibrating with Meytec buffer solution pH 10.01 lets you correct this drift at the alkaline end of the range, which is important when your process runs above neutral pH or when you want to confirm that the probe response remains linear across the full scale.

In advanced calibration routines, the pH 10.01 buffer is used together with neutral and acidic buffers such as pH 7.00 and pH 4.01. This multi point calibration refines the meter response and is recommended wherever precise pH control and documentation are required.

250 ml bottle for regular calibration

The Meytec buffer solution pH 10.01 bottle 250 ml is supplied in a practical screw cap bottle designed for frequent use. The 250 ml volume offers enough buffer for many calibration cycles while remaining easy to handle and store in technical rooms or service vehicles.

  • 250 ml of ready to use alkaline pH 10.01 buffer solution.
  • Robust design bottle with secure cap for repeated opening and closing.
  • Suitable for bench meters, handheld testers and fixed pH controllers.

For best results, pour only a small working volume into a clean container for each calibration and close the main bottle immediately to help preserve the specified pH value over time.

Calibration with Meytec pH 10.01 buffer

The Meytec buffer solution pH 10.01 bottle 250 ml is compatible with most pH meters that accept external buffer solutions. It is intended for calibration and verification of pH probes used in pools, spas, process tanks and other installations where readings above neutral pH are relevant or where a full range calibration is required.

  • Alkaline reference point for multi point calibration procedures.
  • Supports precise adjustment of pH probes at high pH values.
  • Complements neutral and acidic Meytec buffer solutions in a complete set.

Calibration should always follow the instrument manufacturer instructions, including the recommended buffer order, stabilisation time and temperature compensation steps.

Example multi point calibration procedure

A typical multi point calibration using Meytec buffers uses pH 7.00 as the neutral point, pH 4.01 on the acidic side and pH 10.01 on the alkaline side. This combination allows the meter to correct both offset and slope across a wide pH range.

  • Rinse the pH probe with clean water and gently dry with a soft cloth.
  • Calibrate first in pH 7.00 buffer and adjust the meter to read 7.00.
  • Rinse the probe, then calibrate in pH 4.01 buffer if required by the instrument.
  • Rinse again and pour a small amount of pH 10.01 buffer into a clean container.
  • Immerse the probe in the pH 10.01 buffer, wait for a stable value and adjust the reading to 10.01 according to the meter menu.

After calibration, rinse the probe once more before returning it to normal measurement so that no buffer residues enter the process water.

Storage and handling recommendations

To keep the Meytec buffer solution pH 10.01 bottle 250 ml within specification, it should be stored in a cool, dry place away from direct sunlight and heat sources. Good handling practices reduce contamination and extend the useful life of the solution.

  • Always close the bottle tightly immediately after dispensing.
  • Use only clean glass or plastic containers for the working volume.
  • Never pour used buffer back into the original bottle.

When combined with proper probe storage, cleaning and regular calibration using Meytec buffers, this pH 10.01 solution helps maintain stable pH readings and supports precise dosing control in pool and water treatment systems.