Meytec cleaning solution H2O bottle 250 ml

delivery-time

Shipping: 1-2 weeks

14,95 

inc. btw

Can be backordered

Sorry, only items in stock
  • Wordwide shipping

  • Easy returns within 14 days.

  • Certified online store

  • Customized advice

  • Customers give us a score of 9.4/10.

Do you have any questions about this product?
We are happy to provide you with personal
advice about this product.

Ask a question
Meytec cleaning solution H2O bottle 250 ml 14,95  inc. btw

Description

Meytec cleaning solution H2O bottle 250 ml

The Meytec cleaning solution H2O bottle 250 ml is a dedicated rinse and cleaning liquid for pH, ORP and conductivity probes used in swimming pools, spas and water treatment systems. It is designed as a gentle, water based cleaner that helps remove residual chemicals and sample deposits from sensitive measuring surfaces without damaging the electrodes.

Purpose of the H2O cleaning solution

After every measurement, sensor surfaces are left in contact with pool water containing chlorine, salts and dissolved contaminants. If these residues dry on the probe, they can slow the response, distort readings and shorten probe life. The Meytec cleaning solution H2O is used to rinse and clean electrodes after use, removing these deposits before the probe is stored or returned to service.

Unlike aggressive detergents or household cleaners, this water based solution is formulated for use with measuring electrodes, helping to protect delicate glass membranes and reference junctions while keeping them free from visible residues.

Typical applications

Meytec cleaning solution H2O bottle 250 ml is suitable for routine care of most standard electrodes and probes used in pool and spa water analysis. It is commonly used with:

  • Glass pH electrodes on handheld meters and controllers.
  • ORP and redox probes used for disinfection control.
  • Conductivity and TDS probes in water treatment systems.
  • Combination electrodes in portable multi parameter testers.

The solution is intended for regular rinsing and light cleaning between measurements, and as a first step before any deeper chemical cleaning operations recommended by the probe manufacturer.

How to use Meytec cleaning solution H2O

The Meytec cleaning solution H2O bottle 250 ml is simple to integrate into your daily maintenance routine. The goal is to rinse the probe thoroughly in clean solution after it has been in contact with pool water, test samples or calibration liquids.

  • Pour a small amount of cleaning solution into a clean beaker or cup.
  • Rinse the probe briefly with tap or demineralised water to remove bulk residues.
  • Immerse the measuring tip and junction in the Meytec H2O solution and gently move the probe to help detach remaining deposits.
  • Remove the probe, lightly shake off excess liquid and, if needed, finish with a short rinse in demineralised water.

After cleaning, the probe can be placed directly into a calibration buffer or into KCL storage solution according to the manufacturer recommendations.

Maintenance benefits and frequency

Using Meytec cleaning solution H2O regularly helps maintain good probe performance and extends the useful life of electrodes. Clean sensor surfaces respond faster, give more stable readings and require fewer calibration corrections.

  • Reduces build up of scale, salts and organic residues on sensor surfaces.
  • Supports faster stabilisation of readings during calibration and measurement.
  • Helps protect delicate glass bulbs against mechanical cleaning and abrasion.

In normal pool use, a short cleaning step after each measurement session or at least once per day is recommended, with more frequent cleaning in heavily loaded or turbid water.

Storage and handling of the solution

To keep Meytec cleaning solution H2O bottle 250 ml in good condition, it should be stored in a cool, dry place, away from direct sunlight and heat sources. As with all liquids used for analytical work, good handling practices help to avoid contamination.

  • Always close the bottle tightly immediately after dispensing.
  • Use only clean containers for the working volume and replace it regularly.
  • Do not pour used cleaning solution back into the original bottle.

With correct storage and regular use, this water based cleaning solution becomes a simple but effective tool to keep pH, ORP and conductivity probes clean, stable and ready for accurate pool water measurements.

Reviews (0)

Only logged in customers can leave a review.

FAQ

Tips & advices

No selected tips