Salta al contenuto

Pompa di calore Hydro-Pro, tipo Inverter (modello Xp10Dcsi+) – vista esplosa e ricambi

7018546
Certificato Certificato negozio online
Resi facili Resi facili entro 14 giorni
Fai la tua domanda

Elenco dei ricambi

Hydro-Pro - Cintura riscaldante per evaporatore 230 V 65 W 1900 mm - 7020272

56,95 €

Hydro-Pro - Motore del ventilatore per pompa di calore ZWB378D02B 120 W - 7021812

414,45 €

Hydro-Pro - Pala del ventilatore per pompa di calore con inverter 496 mm × 150 mm, foro da 12 mm, rotazione antioraria - 7021815

80,95 €

Flotide/MEGA - Scatola espositiva impermeabile per pompa di calore con inverter (tipo Xp05Csie) - 7010543

31,45 €

Hydro-Pro - Controller con display LED per pompa di calore ad inverter SHHCLEDMM101 - 7020256

226,95 €

Flotide/MEGA - Pannello di visualizzazione a LED con Wi-Fi per pompa di calore con inverter (WiFi02iMM011) - 7023600

252,45 €

Flotide/MEGA - Cinghia per riscaldatore del carter del compressore 230 V 35 W 340 mm - 7020267

44,45 €

Manometro 0–55 bar R410A - 7010518

47,45 €

Flotide/MEGA - Interruttore di flusso dell'acqua con connettore VH-2 (9×7 mm) - 7020257

Flotide/MEGA - Interruttore di flusso dell'acqua con connettore VH-2 (9×7 mm) - 7020257

100,95 €

Flotide/MEGA - Sensore di temperatura dell'acqua in uscita TH5 con spina (6×4) - 7020262

15,95 €

Hydro-Pro - Scambiatore di calore in titanio per pompa di calore Inverter 10 - 7021819

731,95 €

Flotide/MEGA - Sensore di temperatura dell'acqua in entrata TH6 con connettore (6×4) - 7020263

15,95 €

Flotide/MEGA - Tappo per tubi in PP, filettatura maschio da ½", 10 bar, nero - 0121241

3,45 €

Flotide/MEGA - Sensore di temperatura dei gas di scarico TH3 con connettore (6×4) - 7020261

15,95 €

Flotide/MEGA - Pressostato di alta pressione per pompa di calore 3,6–4,2 MPa - 7024793

21,95 €

Flotide/MEGA - Pressostato di bassa pressione 0,1–0,3 MPa (pompa di calore A3/32) - 7024791

21,95 €

Flotide/MEGA - Pressostato di bassa pressione 0,2–0,35 MPa (pompa di calore con inverter Xp05Csie) - 7024792

21,95 €

Hydro-Pro - Scheda di controllo principale per pompa di calore con inverter 7 / 10 / 13 kW (53B) - 7020760

559,45 €

Descrizione

Pompa di calore Hydro-Pro, tipo Inverter (modello Xp10Dcsi+) – vista esplosa e ricambi

This page provides the official exploded-view diagram and full bill of materials for the Hydro-Pro Heat Pump, Type Inverter (Type Xp10Dcsi+), referenced by Hydro-Pro factory number 7018546. The XP10DCSI+ is a single-phase inverter pool heat pump in which a variable-speed compressor and fan motor work together to absorb heat from ambient air and transfer it to pool water via a titanium heat exchanger. The diagram covers every serviceable component from the outer casing panels through to the refrigerant circuit and electrical enclosure. Use the numbered call-outs on the diagram alongside the parts list below to identify and order the exact replacement you need — most visitors locate their part within a few minutes.

Come utilizzare lo schema numerato per individuare il proprio componente

Every numbered call-out in the diagram corresponds directly to a row in the parts table: locate the area of the unit where your fault or wear is occurring, note the position number printed on that call-out, then find the matching row in the table to retrieve the SKU. Work methodically from area to number to SKU rather than scanning the whole list at once — it is much faster. Be aware that some position numbers appear more than once in the diagram because the same component is used in multiple locations; position 30 and position 35, for example, are both described as “Wiring cover”, and positions 39 and 46 are both the “Water connection set” (SKU 7014153) used at the inlet and outlet respectively — always verify which instance applies to your repair. Pay close attention to lettered suffixes: positions 23a and 23b are two distinct LED display variants, and positions 65 and 65B are different main board versions — ordering the wrong lettered variant will result in an incompatible part. Where a SKU is listed as null in the table, that component is not currently sold individually through this catalogue; contact our team if you need guidance. If a position number seems ambiguous on a worn or printed diagram, cross-reference the written description in the table to confirm your selection before adding to the basket.

Main replaceable assemblies on the Hydro-Pro Type Inverter (Xp10Dcsi+)

The air-side assembly centres on the fan system: position 17 is the fan motor (ZWB378D02B, 120 W, SKU 7021812) and position 19 is the matched fan blade (496 mm × 150 mm, 12 mm bore, anticlockwise rotation, SKU 7021815); both items must be compatible with one another, so check the rotation direction before ordering. The motor is housed within the motor tube (pos. 18) and supported by the fan motor bracket (pos. 15), with the top frame (pos. 11) and surrounding casing panels — left side (pos. 16), right (pos. 31), front (pos. 20), back (pos. 38), and front grill (pos. 21) — completing the enclosure. The water-side circuit runs through the titanium heat exchanger (pos. 47, SKU 7021819), which is connected to the pool circuit via water connection sets at both ends (pos. 39 and pos. 46, both SKU 7014153), sealed with red and blue rubber rings at positions 40 and 48. Water flow is monitored by the flow switch at position 42 (VH-2 plug, 9 × 7 mm, SKU 7020257), with inlet and outlet temperature sensors at positions 49 and 44 respectively. The refrigerant circuit comprises the compressor (pos. 27) mounted on damping feet (pos. 28), the 4-way valve (pos. 54) with its associated pipework (pos. 53, 55), the electronic expansion valve (pos. 63), and high- and low-pressure switches (pos. 57, 60, and 61). Frost protection is provided by two heating belts: the evaporator heating belt (pos. 14, 230 V / 65 W / 1,900 mm, SKU 7020272) and the compressor heating belt (pos. 29, 230 V / 35 W / 340 mm, SKU 7020267). The electrical enclosure (pos. 66) houses the main inverter board (pos. 65, SKU 7020760) and is fronted by the waterproof display box (pos. 22, SKU 7010543) carrying the LED display. Refrigerant-circuit pressures are read via the pressure gauge at position 32 (SKU 7010518), and system integrity is protected by the high-pressure switch at position 57 (3.6–4.2 MPa, SKU 7024793) alongside two low-pressure switch variants at positions 60 and 61.

Scelta tra varianti e formati di confezione

The most critical variant choice on this unit is the LED display at position 23: the 23a version (SHHCLEDMM101, SKU 7020256) is the standard inverter display, while 23b (WiFi02iMM011, SKU 7023600) includes integrated Wi-Fi for smartphone control — the two are not interchangeable, so confirm which display your unit was originally fitted with before ordering. A similarly important decision applies to the main board at position 65: SKU 7020760 suits the standard Inverter 7/10 models, whereas the 65B variant (SKU 7020770) is intended for the Inverter 10(B) build and must be paired with the correspondingly suffixed sensor set (the “xxB” variants at positions 44B, 49B, and 56B) — mixing board generations with mismatched sensors will cause incorrect temperature readings. For the temperature sensors at positions 44, 49, and 56, note that each position also carries a “B” variant with a different plug configuration (16 × 4 rather than 6 × 4 for position 56B); always match the plug dimensions to your existing wiring loom. The PP plug at position 50 (½” male thread, 10 bar, SKU 0121241) is a straightforward single-size item, but confirm thread pitch and pressure rating are suitable for your installation before fitting.