Salta al contingut

Norsup bomba de calor, tipus Px inversor (tipus P13X/32) vista desmuntada i peces de recanvi

7024626
Certificat Certificat botiga en línia
Devolucions fàcils Devolucions fàcils dins 14 dies
Fes la teva pregunta

Llista de recanvis

Descripció

Norsup Heat Pump Type PX Inverter (P13X/32) exploded view & spare parts

Aquesta pàgina mostra el diagrama de desmuntatge complet i la llista de materials per al Norsup Heat Pump Type PX Inverter, model P13X/32, carried under Norsup factory reference 7024626. The P13X/32 is a full inverter swimming pool heat pump that varies its heating capacity — by modulating fan and compressor speeds — to suit prevailing weather conditions and air temperatures. It operates on a 230 VAC single-phase supply and uses R32 refrigerant, with a horizontal air-discharge layout. The diagram on this page numbers every internal and external component, and the parts list beneath it links each position directly to a purchasable SKU where stock is held — so you should be able to identify the part you need in a matter of minutes.

Com utilitzar el diagrama numerat per trobar la teva peça

Every call-out number printed on the exploded-view diagram corresponds to exactly one row in the parts table below — locate your area of the unit first (refrigerant circuit, electrical compartment, fan section, or water-side connections), then read off the position number nearest to the component you need. Once you have the position number, find the matching row in the table and note the SKU; that SKU is what you add to your basket. Be aware that some components are referenced more than once in the diagram — this is common for fasteners, gaskets, and small connectors that appear in several sub-assemblies simultaneously, so always cross-check the written description against what you see on the unit before ordering. Position 35 in this BOM is unusual: rather than a single component, it groups a set of accessories and sensors — including temperature sensors, rubber feet, a union coupler, and a winter cover — all listed together under one position; each of those accessories carries its own individual SKU. Where a description includes a footnoted number in brackets, such as positions 3 and 31 marked “(1)” and position 5 marked “(2)”, this indicates the manufacturer has applied a note in the original service document — consult the full diagram notes panel for any quantity or fitment clarification. Always confirm physical dimensions and electrical ratings from the description column (thread size, voltage, pressure rating) before finalising your choice, since a part that looks identical may differ in a critical specification.

Main replaceable assemblies on the Norsup P13X/32

The P13X/32 is organised into four broad service zones, all of which are represented in this diagram. The circuit de refrigerant contains the core heat-pump components: the compressor (pos. 9), el Valvula de 4 vies de reversió (pos. 1) that switches the unit between heating and cooling modes, the electrovàlvula d'expansió electrònica (pos. 2) that meters refrigerant flow, and the evaporator (pos. 20) that extracts heat from the outside air. Norsup units use titanium heat exchangers, and the water-side exchanger for this model — the titanium heat exchanger P13X/32 (pos. 8, SKU 7024945) — is the component through which pool water is actually warmed. Circuit protection is provided by the low pressure switch 0.3 MPa/0.15 MPa (pos. 30, SKU 7011009) i el high pressure switch 3.2 MPa/4.4 MPa (pos. 32, SKU 7011008), which safeguard the compressor against out-of-range refrigerant pressures; the pressure meter (pos. 34, SKU 7026259) is rated for R32 gas down to −15 °C. The water-side connection inclou el water flow switch with glue adapter 32 mm (pos. 4, SKU 7006471), which prevents the unit from running without adequate water flow. The Muntatge del ventilador consists of the motor de ventilador ZWS75-A (pos. 17, SKU 7024943), el fan blade 500 mm × 145 mm with 10 mm anti-clockwise hole (pos. 16, SKU 7024880), i el Suport del motor del ventilador (pos. 19), all protected by the reixa de protecció del ventilador (pos. 15). El electrical compartment acull les main board 2AC32I12WO1 (pos. 24, SKU 7024938), which supports the low-noise variable-speed fan motor and inverter compressor control, along with the relay (pos. 27), reactance (pos. 28), i power supply (pos. 25). The user interface is the LED display Norsup P-series (pos. 13, SKU 7024942), mounted behind the front panel (pos. 18). Wiring connections throughout the unit are made via the 5-way wire connector (pos. 12, SKU 7011025) i 2-way wire connector (pos. 26, SKU 7011019), both held in the connector holder (pos. 11). Structural panels — including the top lid 1002 × 396 mm (pos. 23, SKU 7033051), right panel (pos. 7), front panel (pos. 18), back panel (pos. 21), middle separation panel (pos. 14), and chassis (pos. 10) — complete the enclosure.

Tria entre variants i mides de paquet

Several positions in this BOM carry explicit dimensional or rating information that is essential to ordering the correct part. The fan blade (pos. 16) is specified as 500 mm diameter × 145 mm pitch with a 10 mm centre hole and an anti-clockwise rotation direction — fitting a clockwise blade or an incorrect bore size will either prevent the unit from moving air properly or make it impossible to fit to the motor shaft. The water flow switch (pos. 4) is sized for a 32 mm glue-socket adapter; if your pipework is a different diameter, confirm the adapter size before ordering. The pressure switches (pos. 30 and 32) each carry specific cut-in and cut-out pressure ratings that must match the R32 refrigerant circuit of the P13X/32 — do not substitute generic pressure switches with different set-points. For the accessories grouped under position 35, each item has its own SKU and is sold individually, so identify precisely which sensor, fitting, or accessory you require and order only that line; mixing up the 5K temperature sensor (SKU 7011007) with the 50K exhaust temperature sensor (SKU 7024867), for example, will result in incorrect temperature readings and potential fault codes on the main board.