Aller au contenu

Hydro-Pro - Titanium Heat Exchanger for Type Z14/32 Inverter Heat Pump - 7025163

7025163
1 à 3 semaines
609,95 € impôts inc.
Expédition Expédition 1 à 3 semaines
Certifié Certifié boutique en ligne
Retours faciles Retours faciles dans les 14 jours
Pièce de rechange Vous cherchez une pièce de rechange ?
Aller à la vue éclatée
Question Cherchez-vous des conseils ?
Posez votre question

Hydro-Pro – Titanium Heat Exchanger for Type Z14/32 Inverter Heat Pump

This is the genuine OEM replacement titanium heat exchanger designed specifically for the Hydro-Pro Type Z14/32 Inverter swimming pool heat pump. The heat exchanger is the core component responsible for transferring thermal energy from the refrigerant circuit to your pool water, delivering efficient and reliable heating performance. Replacing a damaged or worn exchanger with a genuine Hydro-Pro part restores the unit to its original specification.

Compatibilité

This heat exchanger is a direct replacement part for the Hydro-Pro Inverter Type Z14/32 heat pump (230 V / 50 Hz / single phase, R32 refrigerant). It is not interchangeable with other models in the Z-series line-up such as the Z7/32, Z11/32, Z16/32 or Z19/32. Always verify your heat pump model number before ordering.

Pourquoi l'authenticité est importante

The Hydro-Pro Type Z14/32 uses a twist-titanium tube-in-PVC heat exchanger, a design that resists corrosion from chlorinated and salt-treated pool water. Titanium’s exceptional chemical resistance protects the exchanger from aggressive pool chemistry, while the PVC housing adds further durability. Using a genuine Hydro-Pro part ensures the correct dimensions, flow characteristics, and materials are maintained, safeguarding both performance and your warranty.

Installation

Replacement of the heat exchanger requires draining the relevant water circuit and disconnecting the refrigerant lines — work that must be carried out by a qualified pool heating technician or certified refrigeration engineer. Ensure the power supply is fully isolated before opening the heat pump cabinet. Chemical dosing equipment should always be positioned downstream of the heat pump to prevent corrosive concentrations from contacting the exchanger.

Informations complémentaires

Modèle compatible : Hydro-Pro Inverter Type Z14/32
Matériau de l'échangeur de chaleur : Twist-titanium tube in PVC
Compatibilité avec les fluides frigorigènes : R32
Tension : 220–240 V / 50 Hz / 1 Phase
Type de pièce : OEM Replacement Component