Profec Single-Jet Cold Water Meter DN20 – 3/4″ Male Thread, MID-Approved, 24VAC Pulse Output

This Profec single-jet water meter is engineered for accurate cold-water measurement in residential, commercial, and irrigation installations. The nickel-plated brass body combines corrosion resistance with long service life, while the blue polycarbonate register cover makes it immediately identifiable as a cold-water unit. With a maximum working pressure of 16 bar and a temperature range of 2°C to 50°C, it handles demanding supply conditions without compromise.

The SD-A pulse output module (24VAC) enables remote reading and integration with building management systems, irrigation controllers, or data loggers — making it a practical choice for greenhouse growers and pool facility managers who need verified consumption data. The meter carries both CE and MID (EN 16-108 / MI-001) certification, satisfying European metrological requirements for billing-grade measurement. Accuracy class 0.1A ensures reliable registration down to the minimum flow rate of 0.1 m³/h.

Especificacions

  • Diàmetre nominal: DN20
  • Connection: 3/4 inch male thread (both ends)
  • Installation length (L): 130 mm
  • Body height: 85 mm
  • Register height from centre-line: 77 mm
  • Material del cos: llautó niquelat
  • Register cover colour: Blue (cold water)
  • Measurement principle: Single jet
  • Accuracy class: 0.1A (Class B)
  • Maximum flow (Q4 / Qmax): 4 m³/h
  • Nominal flow (Q3 / Qn): 2.5 m³/h
  • Minimum flow (Q1): 0.1 m³/h
  • Transitional flow (Q2): 2 m³/h
  • Working pressure (MAP): 16 bar
  • Water temperature range: 2°C – 50°C
  • Pulse output: SD-A type, 24VAC
  • Certifications: CE, MID (EN 16-108, MI-001)
  • Approved for: Cold water (potable)

Compatibilitat

Designed for horizontal or vertical installation in cold potable water systems with 3/4 inch male-thread pipework (DN20). The 130 mm installation length conforms to standard meter-bay dimensions, allowing direct replacement of existing DN20 single-jet meters. The 24VAC SD-A pulse output is compatible with most irrigation controllers, pulse-counting data loggers, and building management systems that accept a dry or low-voltage pulse signal. Not rated for hot water (above 50°C) or steam service.

Informació addicional

Marca: Profec
Diàmetre nominal: DN20
Tipus de connexió: Filfer masculí de 3/4 polzada (ambdós extrems)
Installation length (L): 130 mm
Alçada del cos: 85 mm
Register height from centre-line: 77 mm
Material del cos: Llautó niquelat
Register cover colour: Blau
Principi de mesurament: Single jet
Classe d'exactitud: 0.1A (Class B)
Maximum flow (Qmax / Q4): 4 m³/h
Nominal flow (Qn / Q3): 2,5 m³/h
Transitional flow (Q2): 2 m³/h
Flux mínim (Q1): 0,1 m³/h
Pressió de treball (MAP): 16 bar
Interval de temperatura de l'aigua: 2°C – 50°C
Pulse output type: SD-A
Tensió de sortida de pols: 24VAC
Medium: Aigua potable freda
Certificacions: CE, MID (EN 16-108, MI-001)
MID module: MI-001

En detall

Profec Water Meter Brass Nickel 3/4″ Male Thread DN20 16 bar 24VAC MID
120,95 
Profec Water meter brass nickel plated 3/4" male thread 16bar 0,1A 2m³/h DN20 24VAC blue CE/MID SD-A type single jet — main
  • MID-certified for billing-grade accuracy — legally compliant for metered water billing
  • Nickel-plated brass body resists corrosion in treated pool and irrigation supply water
  • 130 mm face-to-face length fits standard DN20 meter bays for drop-in replacement
  • Integrated 24VAC SD-A pulse output enables remote monitoring without extra sensors
  • 16 bar working pressure suits high-pressure mains supply without additional pressure reduction
  • Rated for cold water only (max 50°C) — not suitable for hot-water or mixed circuits
  • Single-jet design measures flow in one direction only — correct orientation must be observed during installation
  • Pulse output requires a 24VAC supply; installations with DC-only controllers will need a signal converter